Carrier A/c Fan Not Working

Contents

There should be no reason to have to repair it or spend too much time in learning to use it. Inspected the condenser unit outside, and the fan was not turning, and the coolant lines into the house were not cold at all as they should be. Now we have nice cool air again! You'd be quite clumsy to short the 24v while changing out a capacitor BUT, yes, you can take the extra precaution and shut down the furnace power if you're more comfortable have a peek here

There are some electrical situations that could fool us into thinking that so you may want to have that checked out before putting in a motor but it's likely the issue.Evonn The fan started spinning again but for only about 15 minutes before winding down. Reader Question: (May 18, 2015) Aubrey said: when set to cooling the compressor fan stops and starts. Resists turning at all and hum gets real loud when I try.

Ac Unit Fan Not Spinning

Hitmanch472 months ago Cre8tor thanks for reply. Not to say that's "great" but again, not uncommon. Any thoughts?Reply Jim Plummer says: September 19, 2016 at 6:12 pmOrion,You symptoms are pointing toward a bad motor. If the A/C trips the breaker again, read about the reasons why the A/C may trip the breaker.

N the house is not cold as it should be to me i have it on 73 but the thermostat reads 84Reply Jim Plummer says: July 11, 2016 at 6:12 pmTandryn,I Rod3 months ago I was changing the capacitor on my ac unit and the part that goes in the end of the cable that connects to the capacitor broke off. AC man quoted 300 bucks to fix. Ac Fan Capacitor Just ask us!

They likely are not the same rated capacitor and the fan inside needs that to run at the appropriate speed. You have really helped my life. If this was my system, I would not match these two together in the same system. http://www.doityourself.com/forum/air-conditioning-cooling-systems/475582-carrier-c-condenser-fan-not-working.html Line restriction/bad txv?

Is system keeping the house cool at night? Ac Fan Not Working In Car Any restriction of air flow through the coils indoors or outdoors can cause the compressor to run hot.If all of the above is in good shape, then it is time to Does it run when you shut everything off and then turn it on? If the motor hums and does not start techs often try swapping in a new start capacitor.

Ac Compressor Not Running

They run continuously until the indoor thermostat is satisfied when they are operating properly. but could it be the thermistor that is located in the rear opening of the incoming air?Maybe I should measure all three thermistors and what resistance should I expect when room Ac Unit Fan Not Spinning I hope this helps. Ac Inside Fan Not Working Cre8tor3 months ago from Ohio Author Valerie and Maura - Thank you for the feedback!Elizabeth - I don't think you're off base.

Again thank you so much for taking the time to post!! http://haiteq.com/fan-not/carrier-condenser-fan-not-working.php SERVICE REQUEST ESTIMATE REQUEST MAINTENANCE REQUEST COUPONS/REBATES HVAC FINANCING WHAT'S NEW CONTACT US TESTIMONIALS... I push the what I call a reset button and it sometimes starts fan, and sometimes I have to use stick to start fan. All rights reserved. Why Is My Ac Outside Unit Not Turning On

Sign in to report inappropriate content. They took care to cover my hardwood floors where they had to pass through the house and did a great job at cleaning up. Identifying my own installations errors can be challenging since I tend to view the mistake as the correct action when reviewed. Check This Out steven lavimoniere 35,407 views 9:46 Hvac repair:a.c.condenser fan motor not spinning ,no cooling - Duration: 4:10.

When he came out the first time we had turned the a/c unit off for about 24hrs prior his arrival and he said the freon was low he fixed that and Ac Unit Not Turning On InspectAPediaFree Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, RepairHOMEAIRCONDITIONINGDAMAGE ASSESSMENTELECTRICALENERGYSAVINGSENVIRONMENTEXTERIORSFORENSICSHEATINGHOMEINSPECTIONINDOORAIRIAQINSULATIONINTERIORSMOLDCONTAMINATIONNOISEODORSPLUMBINGROOFINGSEPTICSYSTEMSSOLARENERGYSTRUCTUREVENTILATIONWATERSUPPLYEXPERTSDIRECTORYBUILDING ADVISOR.COM - Sister SiteCONTACT US Air Conditioning & Heat Pump Compressor / Condenser Fan Inspection, Diagnosis & Repair FAN, COMPRESSOR I let it go for about 10 minutes.

We seem to have the same issues on and off.

Recently my outdoor fan was not blowing and I checked my fuse box and the switch had jumped off. It's very easy to move around your website and find what you are looking for quickly. Of course they said that it would apply to any repairs I had done. *rolls eyes* Anyway I was in my house yesterday with a broken down a/c, 98 degrees in Ac Fan Motor Please tell Todd and his partner that I appreciate the quality service they provided.

Otherwise you may damage the compressor by overheating it. Any ideas what they might be missing?The AC capacitor was replaced in 2012 along with the Condensate Line cleaned out that same year. InspectAPedia.com editor Daniel Friedman is a contributing author.The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. http://haiteq.com/fan-not/carrier-air-conditioning-fan-not-working.php Let’s explore both.

Today it is 85 degrees outside, my house it at 80 and my thermostat has been at 72 all day. The unit is probably 18 or 20 years old. When I turn it on, I get a quick buzzing sound that lasts ~1 second, but nothing more. After several replacements by servicemen, it's now 45/5 mfd.

Is it possible my compressor is not functioning correctly from the incorrect wiring or overheated when fan stopped working?Reply Jim Plummer says: September 23, 2016 at 11:27 amLiam,Most outdoor units have I am also considering options best I can - as to next steps given the possible things it could be at this point.Reply Jim Plummer says: July 9, 2016 at 2:34 LouKingman2 months ago I have a basic electronics background but in a floor standing Amcor portable AC I don't know exactly where to look for this thing. Touching two of the terminals at the same time with your hand will discharge this power and make for a shocking experience.

The tech from company that installed unit said it was indeed bad and I bought a new one. INDEX to RELATED ARTICLES: ARTICLE INDEX to AIR CONDITIONING & HEAT PUMPS OR use the Search Box found below at Ask a Question or Search InspectApedia ... Unit is 1 1/2 ton, small bungalow 1100 sq ft.HVAC tech recommends a new condenser or a new unit..Any ideas would be greatly appreciated. Dirty filter?

It only stayed on a few minutes before stopping. Condenser fan runs only at unusually slow speed Possible low voltage at the equipment; possible condenser unit control board circuit failure See CONTROL CIRCUIT BOARD, A/C for details. The capacitor looks good, and since the fan spins right up when I reset the circuit breaker, I'm assuming it's not the capacitor. Some indoor units (Heat Pumps) have breakers right on the Air Handler itself.

He is the type of person you would invite to your house for dinner. After a few minutes the fan stopped again. A start capacitor is an electric device that gets the electric motor running at startup by providing a "jolt" of stored electrical energy. The fan on the unit outside of the house does not work unless I push it to jump start it, but I still only get warm air.

>