Carrier Air Conditioner Outside Fan Not Working

Contents

Contact Us DoItYourself.com Mobile Site Privacy Statement Top All times are GMT -7. Then do your checks on the cap. Different colored wires go to different terminals. That would be an additional $334.00 for the tech to do. have a peek here

This started sort of suddenly yesterday afternoon when we noticed the temperature rising. After driving all over God's green earth I finally found a place willing to sell me a capacitor. I've got a Carrier 38TUA-024 unit. How do I test whether power is being delivered to the motor?

Ac Unit Fan Not Spinning

Israelhvac 5.293 visualizaciones 8:20 Do-it-Yourself Replacing Bad Air Conditioning Condenser Fan Motor - Duración: 9:48. The plunger gets stuck? Perhaps you're about to luck out by making a simple repair that will only cost you a few dollars and take very little time. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.

Attached Images Sponsored Links 07-27-12,10:32 AM #2 Gunguy45 Super Moderator Join Date Dec 2007 State AZ Posts 19,382 Looks like the top of the cap is swollen to me....rusty for Motor is there in the can, you are right again.Going to re-check it soon.I went to re-measure all wires.On the fan, I was wrong because I ignored the scale! Disconnect the wires. Ac Fan Not Working In Car It may be a good time to get a second opinion from an a/c technician.JimReply Orion says: September 18, 2016 at 5:28 pmJim,My AC is blowing plenty of air through the

You see, the capacitor is there to give a boost to the fan motor upon startup. Ac Compressor Not Running I know these terms are very confusing, open means no circuit and open means open motor, a motor with openings in the sides or rear, totally enclosed is completely closed frame Understanding The Electrical Wiring In An Air Conditioner. - Duración: 22:21. Here Are Some Potential ExplanationsYour central air conditioner has two fans: one located inside that blows cool air for your home and one located outside that blows over condenser coils in

The customer ends up angry, contractor needs to find the "why" if something happens more than once on major components because they don't just go bad that often without reason.Lacrosse - Ac Fan Capacitor InspectAPedia.com editor Daniel Friedman is a contributing author.Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. If I recall, it will power up, won't blow the fuses right away, you have voltage, you even have control voltage, should be the two little wires in the box in If your motor requires a 5 mf capacitor, then the symptoms are pointing toward a bad motor.JimReply Jaece says: July 25, 2016 at 2:52 pmThank you for quick response.Reply M says:

Ac Compressor Not Running

I turn the system off via the thermostat, and it seems no matter how long I leave it off for, I still have the same problem - until the following morning Replacing the compressor is the equivalent of replacing your car’s engine. Ac Unit Fan Not Spinning Additionally, continuity is present from power to ground indicating direct shortage inside of compressor. Why Is My Ac Outside Unit Not Turning On So if your contact is pulling in you should be able to watch it go "click" and move in, and you get voltage.

or do I need a new motor? navigate here Or do you have side discharge. Or did the professional give me the wrong capacitor? If fan switch set in "On" mode from "Auto" nothing coming out of vents until late evening.Elizabeth if you see my post please let us know if your problem resolved?Thank you Ac Inside Fan Not Working

Cargando... It's been over three to four repairs since we have been here. The capacitor is likely mounted to the unit by a metal band that has only one screw to remove. Check This Out Install them, set to cool, if contactor does not click closed, measure voltage at the two little control wires again.

Either way, we are going to find the condenser fan, find it's lead to the cap, and if a two value, we are going to tie it on the compressor side, Ac Unit Not Turning On What I don't get: if a coil in a motor got burnt and broken, why would the motor show some resistance to ground?I went on the mission you sent me!Here are sahil chhikara816 months ago WOW GREAT MAY BE I HAVE TEACHER LIKE YOU IN MECHNICAL STUDIES Lilleyth16 months ago from Mid-Atlantic This is a GREAT hub.

Any thoughts?Reply Jim Plummer says: September 19, 2016 at 6:12 pmOrion,You symptoms are pointing toward a bad motor.

Capacitor was bulging like picture of all bad ones I've seen on Internet. There can be several other devices before the voltage is allowed to get to the outside unit, including the condensation box, or any other relay you might find. Troubleshot to bad part of cap using Fluke DVM & proved compressor running OK and Fan also running connected briefly to compressor side of cap.Installed exact replacement cap & compressor now Ac Unit Fan Motor Search "HVAC supply" in google maps and a local AC supply store sells it.

I assume the current on capacitor is AC, right? Expert: Will replied6 years ago. If motor shaft had axial motion [side to side] bearings are bad, motor is bad. I have had the AC installers out here dozens of times and they cannot say what is wrong. this contact form mandy16 months ago My central air unit was working fine last night but today nothing.

Tech "services" cost me $190 of which the dual capacitor part was $120. Normally a failed motor will not show open all the way, on all leads. Our AC unit had the characteristic loud hum but no spinning of fan blades. If I walk up to a unit and see a cap is bad and it's older, home owner hasn't had it done in a while, I replace the cap and know

There is no type of noise coming from itReply Jim Plummer says: July 7, 2016 at 5:26 pmSol,If the outdoor unit is not running, start with checking the power going to For various reasons, your capacitor can go bad and stop working properly, which will force one of your system’s fans to stop spinning. If it trips again, then check the wiring in the furnace/air handler for signs of damage and repair as necessary.If the blower is running but the fan on the outside unit An overheated motor will restart and run after it cools down.

If there are problems with either one of these fans, your home will not be able to cool properly. Not to say that's "great" but again, not uncommon. Fan is spinning motor is running.

>